Unvented Roof Assembly Detail
It s not and so code doesn t require r value ratios.
Unvented roof assembly detail. Insufficient fill below the impermeable insulation layer. Read all of r806 5 carefully. If you don t want to use sips or nailbase there are four basic approaches. However as the future owner i m beginning maybe a bit too.
Martin s post focuses on the marketing of owens corning 039 s propink unvented attic insulation system. The unvented attic space is completely contained within the building thermal envelope. Yes unvented roof assemblies can be insulated with fiberglass a wufi post and not just in climate zones 2b amp. Recent building codes only allow unvented roof assemblies for pitches 3 12 and greater irc 2015 section r806 5 2 7.
This is a mis interpretation of the code. In the process of construction. The point is that the inner face of that first layer the air barrier layer of insulation should always be warmer than the dew point or you ll get water in your roof. Currently have a standing seam metal room installed over synthetic felt over osb.
Unvented roofs operate by the principle that venting is not necessary to control moisture accumulation. Before constructing a flat roof assembly please refer to the unvented roof assembly comments under 6 2 vented and unvented roof assemblies and if applicable 6 3 parapet walls. Unvented roof assemblies should be insulated either with air impermeable insulation rigid foam or spray polyurethane foam or with a combination of foam and air permeable insulation. The plan is to spray open cell foam under the roof deck.
Figure 6 describes open cell spray foam as air permeable. This is how to detail an unvented roof assembly for flat and low slope roofs. There will be ducting and other hvac equipment in the attic. This document provides a brief description of different types of unvented roof assemblies and the benefits of unvented roof construction.
In some climates it requires a vapor barrier. No insulation installed yet. Unvented roof assemblies are becoming an increasingly common construction alternative to traditional vented roofs. If it all sounds simple there is certainly room for error.
Unvented attic assemblies spaces between the ceiling joists of the top story of the roof rafters shall be permitted if all of the following conditions are met. This is the recommendation of all three local insulation installers. If not properly detailed partial penetrations into the unvented roof assembly for things like can lights or ceiling fans can undermine the insulation and or air tightness strategies alluded to above. The key detail is that the air impermeable insulation must be suitably thick to stop condensation in the assembly.